Applications: For use in measurement of potable cold water in commercial and industrial services where flow is in one direction only.
Operation: At low flow rates, the water is diverted up through a bypass to the disc chamber. Leaving the chamber's outlet port, water flows beyond the turbo and main valve. As the flow rate increases, a pressure differential is created which opens the main valve. The water then flows straight through the turbine chamber in addition to a portion still flowing through the disc chamber before exiting the meter. Rotor and disc movement are transmitted by magnetic drive couplings to individual register odometers.
Operating Performance: With it's patented design, the Badger® Recordall Compound meter meets or exceeds registration accuracy for low flow rate, normal operating flow rates, maximum continuous operation flow rate, and changeover flow rate as specifically stated in AWWA Standard C702.
Construction: Badger Recordall Compound meter construction which complies with ANSI and AWWA C702 standards, consists of three basic components: meter housing, interchangeable measuring elements and single, sealed direct reading registers. The measuring element consist of the disc measuring chamber, turbo head assembly and high flow valve assembly.
To simplify maintenance, the registers and measuring elements can be removed without removing the meter housing from the installation.
Magnetic Drive: Direct magnetic drive, through the use of high- strength magnets, provides positive, reliable and dependable register coupling for straight-reading or remote reading options.
Sealed Registers: The standard registers consists of a straight- reading odometer-type totalization display, 360° test circle with center sweep hand and flow finder to detect leaks. Register gearing consists of self-lubricating thermoplastic gears to minimize friction and provide long life. Permanently sealed; dirt, moisture, tampering and lens fogging problems are eliminated. Multi-position register simplifies meter installation and reading. Automatic meter reading and close proximity systems are available for all Compound Series meters. (See back of sheet for additional information.) All reading options are removable from the meter without disrupting water service.
Meter Reading Technologies: The Itron® ERT®, ORION® and TRACE® meter reading systems are available for all Recordall Compound Series meters. An optional summator or Read-o-Matic®summator/converter can be provided as an integral part of the register assembly. (See back of sheet for additional information.)
Tamper-Proof Features: Tamper resistant register provides protection from unauthorized personnel.
Strainer: A separate strainer is recommended to protect the measuring element but is not a requirement. See Technical Brief PS-T-1 for strainer dimensions.
Maintenance: Badger Recordall Compound meters are designed and manufactured to provide long-term service with minimal maintenance.
When maintenance is required, it can be performed easily either at the meter installation or at any other convenient location. As an alternative to repair by the utility, Badger offers various maintenance and meter component exchange programs to fit the needs of the utility.
Connections: Companion flanges for installation of meters on various pipe types and sizes are available in cast iron or bronze as an option.
Standard: 3/4" drain plug.
Specifications
Type |
N/A Cold Water |
Size |
N/A 3" (DN 80 mm) |
Typical Operating Range (100% ±1.5%) |
N/A 1/2 - 450 gpm0.1 to 102 m³/h |
Maximum Continuous Flow |
N/A 400 gpm90.3 m³/h |
Pressure Loss at Maximum Continuous Flow |
N/A 0.41 bar at 90.3 m³/h 6.0 PSI at 400 gpm |
Pressure Loss at Crossover |
N/A 4 psi0.28 bar |
Minimum Crossover Accuracy |
N/A 97 % |
Maximum Operating Pressure |
N/A 150 psi10 bar |
Maximum Operating Temperature |
N/A 120 ºF49 ºC |
Meter Flanges |
N/A 3" Round Flanges, Class 150 |
Register Type |
N/A Automatic Meter Reading and Close Proximity units optional. Straight reading, permanently sealed magnetic drive standard |
Low Flow Registration |
N/A 1/4 gpm0.06 m³/h1,000,000 Cubic Feet (1 cubic ft./sweep hand revolution.) 10,000,000 Gallons (10 gallons/sweep hand revolution.) 100,000 m³/sweep hand revolution. (0.1 m³/sweep hand revolution.) |
High Flow Registration |
N/A 1,000,000 m³ (1 m³/sweep hand revolution.) 10,000,000 Cubic Feet (10 cubic ft./sweep hand revolution.) 100,000,000 Gallons (100 gallons/sweep hand revolution.) |
Construction Material
Housing and Cover Material |
N/A Cast Bronze (B81), Low Lead Alloy |
Turbo Cast Head Material |
N/A Cast Bronze (B81), Low Lead Alloy |
Nose Cone and Straightening Vanes Material |
N/A Thermoplastic |
Rotor Material |
N/A Thermoplastic |
Rotor Radial Bearings Material |
N/A Lubricated Thermoplastic |
Rotor Thrust Bearings Material |
N/A Sapphire Jewels |
Rotor Bearing Pivot Material |
N/A Passivated 316 Stainless Steel |
Calibration Mechanism Material |
N/A Stainless Steel And Thermoplastic |
Measuring Chamber and Disc Material |
N/A Thermoplastic |
High Flow Valve Material |
N/A Thermoplastic / Stainless Steel |
Magnet Material |
N/A Ceramic |
Register Lens Material |
N/A Glass |
Register Housing and Cover Material |
N/A Thermoplastic or Bronze |
Trim Material |
N/A Stainless Steel |
Proper Installation
N/A
The following installation guidelines will insure optimum field performance and reliability when installing a Badger® Compound Series meter. |