Capacity : 400 gpm (25.24 lpm)
Head : 48 ft (14.6 m)
Horizontal and Vertical Discharge
The 3WHV and V3WHV series non-clog pumps are designed primarily for Commercial applications such as: Schools and Churches, industrial plants, shopping centers, apartments and condominiums, marinas, interstate rest stops, sewage collection systems, campgrounds, motels, restaurants, office and commercial buildings, state and federal parks, hospitals and nursing homes, dewatering, trailer parks and treatment plants. This pump can be installed on legs (vertical discharge) or with a quick-disconnect slide rail system. Its ability to handle 2:/2-inch spherical solids makes it ideal for most light to medium commercial installations.
Advantages By Design
High efficiency hydraulic design cuts pumping costs and extends life of fluid end components.
- Two-vane rounded port impellers handle solids with ease at high operating efficiencies.
- Modified constant velocity volute offers quiet operation, low radial loads over extended portion of performance curve.
Durable motor will deliver many years of reliable service.
- Oil-filled motor for maximum heat dissipation and constant bearing lubrication.
- On winding overload (single phase only) protects motor from over current and heat conditions.
Specifications
Head |
N/A 48 ft14.6 m |
Liquids Handling |
N/A Raw Unscreened Sewage|Effluent|Storm Water |
Intermittent Liquid Temperature |
N/A up to 140 ºFup to 60 ºC |
Winding Insulation Temperature. (Class B) |
N/A 266 ºF130 ºC |
Motor Electrical Data1 | N/A 1-5 HE 230V 1Ø, 60 Hz 1-5 HP 200/230/460/575V 3Ø, 60 Hz 1750 RPM |
Acceptable pH Range |
N/A 6 to 9 |
Specific Gravity |
N/A 0.9 to 1.1 |
Viscosity |
N/A 28 to 35 SSU |
Discharge, Flanged Centerline. (Horizontal or Vertical) |
N/A 3 in76.2 mm |
Minimum Sump Diameter (Duplex) |
N/A 60 in1.5 m |
Power |
N/A 5 hp |
Voltage |
N/A 230 V |
Phase |
N/A 1 |
Frequency |
N/A 60 Hz |
Start |
N/A 101 A23.2 kV·A |
Run |
N/A 34 A4.0 kW7.8 kV·A |
NEC Code Letter |
N/A J |
Service Factor |
N/A 34 A4.0 kW1.0 |
Capacity |
N/A 400 gpm25.24 lpm |
Note |
N/A Consult factory for applications outside of these recommendations |
Construction Material
Motor Housing Material |
N/A Cast Iron, Class 30, ASTM A48 |
Seal Housing Material |
N/A Cast Iron, Class 30, ASTM A48 |
Volute Case Material |
N/A Cast Iron, Class 30, ASTM A48 |
Cord Cap Material |
N/A Cast Iron, Class 30, ASTM A48 |
Enclosed 2-Vane Impeller Material |
N/A Ductile Iron, Class 65 |
Power Cord Material |
N/A 20 ft. SOOW |
Control Cord Material |
N/A 20 ft. SOOW |
Standard Double Tandem Mechanical Seal Material |
N/A Carbon & Ceramic, Single, Type 21 |
Optional Double Tandem Mechanical Seal Material |
N/A Tungsten, Carbide |
Pump Shaft Material |
N/A 416 SST |
Motor Shaft Material |
N/A 416 SST |
Fasteners Material |
N/A 300 series SST |
- 1 Single phase motors are capacitor start type. Myers control panels or capacitor kits are recommended for proper operation and warranty.