Capacity : 700 gpm (2,650 lpm)
Head : 165 ft (50 m)
Standard (4VE) and Explosion-proof (4VEX) Construction
The 4VE and 4VEX (Explosion-proof) Submersible Wastewater Pumps are a heavy-duty 4" non-clog series capable of passing a full 3" spherical solid. Myers rounded port, single vane, enclosed impeller prevents solids from binding or clogging and offer high operating efficiencies to cut your pumping costs. The 4VE series modified constant velocity volute case provides smooth operation over an extended portion of the performance curve for longer seal and bearing life and is for use in municipal lift stations, treatment plants and industrial waste applications. Myers offers a complete line of wastewater pumps, lift-out rail assemblies, controls and accessories to meet your needs.
Advantages By Design
High efficiency hydraulic design cuts pumping costs and extends the life of the pump.
- Single vane, rounded port, enclosed impeller handles 3" solids with ease at high operating efficiencies.
- Non-clogging design for trouble-free operation.
- Produces high heads.
Durable motor will deliver many years of reliable service.
- Class H insulation.
- Continuous duty/VFD rated.
- Oil-filled motor for maximum heat dissipation and constant bearing lubrication.
- Internal thermal overload protection.
- Double tandem shaft seals prevent sewage from entering motor.
- Internal seal leak probes warn of moisture entry.
- Triple sealed power and control cables.
Specifications
Head |
N/A 165 ft50 m |
Solids Handling |
N/A 3 in76 mm |
Liquids Handling |
N/A Effluent Raw Unscreened Sewage Storm Water |
Intermittent Liquid Temperature |
N/A up to 140 ºFup to 60 ºC |
Winding Insulation Temperature. (Class H) |
N/A 356 ºF180 ºC |
Motor Electrical Data |
N/A
1750 RPM 20 - 30 HP 200/230/460/575 volts 3 phase, 60 Hz |
Acceptable pH Range |
N/A 6 to 9 |
Specific Gravity |
N/A 0.9 to 1.1 |
Viscosity |
N/A 28 to 35 SSU |
Horizontal Discharge Flanged Centerline |
N/A 4 in 125 lb ANSI 101.6 mm |
Speed |
N/A 1750 rpm |
Power |
N/A 20 hp |
Voltage |
N/A 460 V |
Phase |
N/A 3 |
Frequency |
N/A 60 Hz |
Start |
N/A 145 A115.5 kV·A |
Run |
N/A 30 A21.2 kW23.9 kV·A |
NEC Code Letter |
N/A G |
Service Factor |
N/A 36 A26.1 kW1.2 |
Capacity |
N/A 700 gpm2,650 lpm |
Note |
N/A Consult factory for applications outside of these recommendations. |
Construction Material
Motor Housing Material |
N/A Cast Iron, Class 30, ASTM A48 |
Seal Housing Material |
N/A Cast Iron, Class 30, ASTM A48 |
Volute Case Material |
N/A Cast Iron, Class 30, ASTM A48 |
Cord Cap Material |
N/A Cast Iron, Class 30, ASTM A48 |
Impeller Material |
N/A Ductile Iron, Class 65, ASTM A536 |
Power Cord Material |
N/A 25 ft. SO 25 ft. SOOW |
Control Cord Material |
N/A 25 ft. SO 25 ft. SOOW |
Standard Double Tandem Mechanical Seal Material |
N/A Carbon & Ceramic, Type 21 |
Optional Double Tandem Mechanical Seal Material |
N/A Lower Tungsten, Carbide |
Pump Shaft Material |
N/A 416 SST |
Motor Shaft Material |
N/A 416 SST |
Fasteners Material |
N/A 300 series SST |
Volute Wear Ring Material |
N/A Brass |