Capacity : 315 gpm (19.9 lps)
Head : 100 ft (30.4 m)
Standard (3RH) and Explosion-Proof (3RHX) Construction
Myers 3RH and 3RHX (explosion-proof) submersible wastewater pumps are the right choice when difficult to pump fibrous or stringy solids are to be expected.The 3RH/3RHX series provides smooth, vibration-free operation when operating at heads higher than peek efficiency. For use in commercial lift stations, treatment plants and industrial waste applications. Myers offers a complete line of wastewater pumps, lift-out rail assemblies, controls and accessories to meet your needs.
Advantages By Design
Passes Stringy Trash, Fibrous Wastes, Slurries, and other difficult to pump Solids that standard enclosed or semi-open Impellers can not.
- Recessed impeller design has completely open passage in volute.
- Pumping action is by Vortex; solids can not get caught in impeller volute.
- Operates without vibration or cavitation over entire performance curve. Operates near shut-off without harming pump.
Durable motor will deliver many years of reliable service.
- Recessed impeller greatly increases bearing life by reducing radial load.
- Oil-filled motor for maximum heat dissipation and constant bearing lubrication.
- Heat sensor thermostats imbedded in windings protect motor from overheat conditions.
- Seal leak probes warn of moisture entry; helps prevent costly motor burnout.
Available with optional F.M. approval for use in class 1, Groups C and D hazardous locations (3RHX only)
Specifications
Head |
N/A 100 ft30.4 m |
Liquids Handling |
N/A Effluent Fibrous Wastewater Raw Unscreened Sewage Storm Water |
Solids Handling (Diameter) |
N/A 2 in50.8 mm |
Intermittent Liquid Temperature |
N/A up to 140 ºFup to 60 ºC |
Winding Insulation Temperature. (Class F) |
N/A 311 ºF155 ºC |
Motor Electrical Data |
N/A 3450 RPM 3-5 HP 230V 1Ø, 60 Hz 3-7 1/2 HP 200/230/460/575V, 3Ø, 60 Hz |
Acceptable pH Range |
N/A 6 to 9 |
Specific Gravity |
N/A 0.9 to 1.1 |
Viscosity |
N/A 28 to 35 SSU |
Horizontal Discharge Flanged Centerline |
N/A 125 lb. ANSI 3 in 76 mm |
Power |
N/A 3 hp |
Voltage |
N/A 230 V |
Phase |
N/A 3 |
Frequency |
N/A 60 Hz |
Start |
N/A 56.6 A22.5 kV·A |
Run |
N/A 8.6 A3.2 kW2.3 kV·A |
NEC Code Letter |
N/A J |
Service Factor |
N/A 11.5 A4.3 kW1.2 |
Capacity |
N/A 315 gpm19.9 lps |
Note |
N/A Consult factory for applications outside of these recommendations |
Construction Material
Motor Housing Material |
N/A Cast Iron, Class 30, ASTM A48 |
Seal Housing Material |
N/A Cast Iron, Class 30, ASTM A48 |
Volute Case Material |
N/A Cast Iron, Class 30, ASTM A48 |
Cord Cap Material |
N/A Cast Iron, Class 30, ASTM A48 |
Recessed Impeller Material |
N/A Ductile Iron, Class 65, ASTM A536 |
Power Cord Material |
N/A 25 ft. SOOW |
Control Cord Material |
N/A 25 ft. SOOW |
Standard Double Tandem Mechanical Seal Material |
N/A Carbon & Ceramic, Type 21 |
Optional Double Tandem Mechanical Seal Material |
N/A Lower Tungsten, Carbide |
Pump Shaft Material |
N/A 416 SST |
Motor Shaft Material |
N/A 416 SST |
Fasteners Material |
N/A 300 series SST |